  1. 10    ! *********************************************************************
  2. 20    ! Example: Function Generator
  3. 30    !
  4. 40    ! This program shows how a panel, menu, and pushbuttons can be
  5. 50    ! used to construct a front panel for a function generator.
  6. 60    !
  7. 70    ! *********************************************************************
  8. 80    !
  9. 90    ! This part of the program creates a panel with one menu selection.
  10. 100   ! Four menu buttons are put into the menu. When any of these menu
  11. 110   ! items is selected, an appropriate subroutine is called.
  12. 120   !
  13. 130   DIM Attr$(3)[15],Attr(3)
  14. 140   COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  15. 150   ASSIGN @Fgen_panel TO WIDGET "PANEL";SET ("TITLE":" Example: Function Generator","X":150,"Y":80,"WIDTH":240,"HEIGHT":200,"MAXIMIZABLE":0,"RESIZABLE":0)
  16. 160   CONTROL @Fgen_panel;SET ("SYSTEM MENU":"Quit")
  17. 170   ON EVENT @Fgen_panel,"SYSTEM MENU" GOTO Finis
  18. 180   !
  19. 190   ASSIGN @Fgen_main TO WIDGET "PULLDOWN MENU";SET ("LABEL":"Control Menu"),PARENT @Fgen_panel
  20. 200   ASSIGN @Frequency TO WIDGET "MENU BUTTON";SET ("LABEL":"Frequency"),PARENT @Fgen_main
  21. 210   ASSIGN @Amplitude TO WIDGET "MENU BUTTON";SET ("LABEL":"Amplitude"),PARENT @Fgen_main
  22. 220   ASSIGN @Dc_offset TO WIDGET "MENU BUTTON";SET ("LABEL":"DC Offset"),PARENT @Fgen_main
  23. 230   ASSIGN @Function TO WIDGET "MENU BUTTON";SET ("LABEL":"Function"),PARENT @Fgen_main
  24. 240   ASSIGN @Modulation TO WIDGET "CASCADE MENU";SET ("LABEL":"Modulation"),PARENT @Fgen_main
  25. 250   ASSIGN @Am TO WIDGET "MENU TOGGLE";SET ("LABEL":"AM"),PARENT @Modulation
  26. 260   ASSIGN @Pm TO WIDGET "MENU TOGGLE";SET ("LABEL":"PM"),PARENT @Modulation
  27. 270   !
  28. 280   !  Initial values for the controls
  29. 290   !
  30. 300   Freq=1000
  31. 310   Ampl=.001
  32. 320   Ampl_unit=0
  33. 330   Offset=0
  34. 340   Func=0
  35. 350   !
  36. 360   ! Displays for the values of the controls. The displays are actually
  37. 370   ! pushbuttons and the label for each button is used to display its
  38. 380   ! current value.
  39. 390   !
  40. 400   Attr$(0)="X"
  41. 410   Attr$(1)="Y"
  42. 420   Attr$(2)="WIDTH"
  43. 430   Attr$(3)="HEIGHT"
  44. 440   Attr(0)=30                   ! X position
  45. 450   Attr(1)=8                    ! Y position
  46. 460   Attr(2)=178                  ! width
  47. 470   Attr(3)=33                   ! height
  48. 480   !
  49. 490   ASSIGN @Freq_disp TO WIDGET "PUSHBUTTON";SET (Attr$(*):Attr(*),"LABEL":VAL$(Freq)&" Hz"),PARENT @Fgen_panel
  50. 500   Attr(1)=Attr(1)+Attr(3)
  51. 510   ASSIGN @Ampl_disp TO WIDGET "PUSHBUTTON";SET (Attr$(*):Attr(*),"LABEL":VAL$(Ampl)&" V p-p"),PARENT @Fgen_panel
  52. 520   Attr(1)=Attr(1)+Attr(3)
  53. 530   ASSIGN @Offs_disp TO WIDGET "PUSHBUTTON";SET (Attr$(*):Attr(*),"LABEL":VAL$(Offset)&" V offset"),PARENT @Fgen_panel
  54. 540   Attr(1)=Attr(1)+Attr(3)
  55. 550   ASSIGN @Func_disp TO WIDGET "PUSHBUTTON";SET (Attr$(*):Attr(*),"LABEL":"SINE"),PARENT @Fgen_panel
  56. 560   !
  57. 570   ! When either the menu is pulled down, or the display is clicked, call
  58. 580   ! a routine to change that control.
  59. 590   !
  60. 600   ON EVENT @Frequency,"ACTIVATED",1 CALL Set_frequency
  61. 610   ON EVENT @Function,"ACTIVATED",1 CALL Set_function
  62. 620   ON EVENT @Amplitude,"ACTIVATED",1 CALL Set_amplitude
  63. 630   ON EVENT @Dc_offset,"ACTIVATED",1 CALL Set_offset
  64. 640   ON EVENT @Freq_disp,"ACTIVATED",1 CALL Set_frequency
  65. 650   ON EVENT @Func_disp,"ACTIVATED",1 CALL Set_function
  66. 660   ON EVENT @Ampl_disp,"ACTIVATED",1 CALL Set_amplitude
  67. 670   ON EVENT @Offs_disp,"ACTIVATED",1 CALL Set_offset
  68. 680   !
  69. 690   ! Event handling for modulation toggles in the menu
  70. 700   !
  71. 710   ON EVENT @Am,"CHANGED",1 CALL Toggle_am
  72. 720   ON EVENT @Pm,"CHANGED",1 CALL Toggle_pm
  73. 730   !
  74. 740   LOOP
  75. 750     WAIT FOR EVENT
  76. 760   END LOOP
  77. 770 Finis: END
  78. 780   SUB Set_frequency
  79. 790   !
  80. 800   ! This routine sets the value of frequency.
  81. 810   !
  82. 820     COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  83. 830     !
  84. 840     ! The user is allowed to enter the new frequency in any of three units.
  85. 850     ! A cancel button is included in case the user makes a mistake.
  86. 860     !
  87. 870     DIM Btn$(3)[6],Freq$[20]
  88. 880     Btn$(0)="Hz"
  89. 890     Btn$(1)="kHz"
  90. 900     Btn$(2)="MHz"
  91. 910     Btn$(3)="Cancel"
  92. 920     !
  93. 930     ! Use a STRING dialog to get the new frequency. This dialog returns
  94. 940     ! a string so a conversion must be done.
  95. 950     !
  96. 960     DIALOG "STRING","",Btn;SET ("VALUE":VAL$(Freq),"TITLE":"Enter Frequency","DIALOG BUTTONS":Btn$(*),"DEFAULT BUTTON":0),RETURN ("VALUE":Freq$)
  97. 970     !
  98. 980     IF Btn=3 THEN SUBEXIT              ! Cancel was clicked
  99. 990     ON ERROR GOTO Cant_convert
  100. 1000    Freq=VAL(Freq$)                    ! convert to a number
  101. 1010    OFF ERROR
  102. 1020    !
  103. 1030    ! The value is checked for validity. The valid range might depend on
  104. 1040    ! function, but that case is not handled.
  105. 1050    !
  106. 1060    Freq=DROUND(Freq*10^(3*Btn),11)    ! apply the suffix and round
  107. 1070    IF Freq>2.0E+7 THEN Frequ=2.0E+7
  108. 1080    CONTROL @Freq_disp;SET ("LABEL":VAL$(Freq)&" Hz")
  109. 1090    !
  110. 1100    ! If actual instruments were being controlled, the OUTPUT statement
  111. 1110    ! would be here.
  112. 1120    !
  113. 1130    SUBEXIT
  114. 1140 Cant_convert:   !
  115. 1150    !
  116. 1160    ! The string could not be converted to a number. Display an error
  117. 1170    ! message and ask again.
  118. 1180    !
  119. 1190    DIALOG "ERROR",Freq$&CHR$(10)&"is not recognizable as a number.";SET ("TITLE":"Can't convert to a number")
  120. 1200    OFF ERROR
  121. 1210    GOTO 960
  122. 1220  SUBEND
  123. 1230  SUB Set_function
  124. 1240    COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  125. 1250    DIM Func$(5)[10]
  126. 1260    Func$(0)="SINE"
  127. 1270    Func$(1)="SQUARE"
  128. 1280    Func$(2)="TRIANGLE"
  129. 1290    Func$(3)="POS RAMP"
  130. 1300    Func$(4)="NEG RAMP"
  131. 1310    Func$(5)="DC only"
  132. 1320    !
  133. 1330    ! The button value is placed in a temporary variable in case Cancel
  134. 1340    ! is clicked. Only if OK is clicked is the value transferred to
  135. 1350    ! the actual variable which contains the function.
  136. 1360    !
  137. 1370    DIALOG "LIST","",Btn;SET ("TITLE":"Select Function","ITEMS":Func$(*),"SELECTION":Func,"DEFAULT BUTTON":0),RETURN ("SELECTION":A)
  138. 1380    IF Btn=1 THEN SUBEXIT
  139. 1390    Func=A
  140. 1400    CONTROL @Func_disp;SET ("LABEL":Func$(Func))
  141. 1410    !
  142. 1420    ! If DC only function is selected then the amplitude control has
  143. 1430    ! no effect.  The button and menu are deactivated.
  144. 1440    !
  145. 1450    IF Func=5 THEN
  146. 1460      CONTROL @Ampl_disp;SET ("SENSITIVE":0)
  147. 1470      CONTROL @Amplitude;SET ("SENSITIVE":0)
  148. 1480    ELSE
  149. 1490      CONTROL @Ampl_disp;SET ("SENSITIVE":1)
  150. 1500      CONTROL @Amplitude;SET ("SENSITIVE":1)
  151. 1510    END IF
  152. 1520  SUBEND
  153. 1530  SUB Set_amplitude
  154. 1540    COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  155. 1550    DIM Btn$(5)[7],Ampl$[20]
  156. 1560    Btn$(0)=" V p-p"
  157. 1570    Btn$(1)=" mV p-p"
  158. 1580    Btn$(2)=" V RMS"
  159. 1590    Btn$(3)=" mV RMS"
  160. 1600    Btn$(4)=" dBm"
  161. 1610    Btn$(5)="Cancel"
  162. 1620    DIALOG "STRING","",Btn;SET ("VALUE":VAL$(Ampl),"TITLE":"Enter Amplitude","DIALOG BUTTONS":Btn$(*),"DEFAULT BUTTON":0),RETURN ("VALUE":Ampl$)
  163. 1630    IF Btn=5 THEN SUBEXIT             ! Cancel was clicked
  164. 1640    ON ERROR GOTO Cant_convert
  165. 1650    Ampl=VAL(Ampl$)
  166. 1660    OFF ERROR
  167. 1670    Ampl_unit=Btn
  168. 1680    IF Btn=1 OR Btn=3 THEN
  169. 1690      Ampl=Ampl*.001                  ! A mV button was selected
  170. 1700      Ampl_unit=Ampl_unit-1           ! Change to V unit
  171. 1710    END IF
  172. 1720    IF Btn<4 THEN
  173. 1730      !
  174. 1740      ! A volt button was used. Round and check for limits. The limit
  175. 1750      ! might also depend on the dc offset.
  176. 1760      !
  177. 1770      Ampl=ABS(PROUND(Ampl,-3))
  178. 1780      IF Ampl>5 THEN Ampl=5
  179. 1790    ELSE
  180. 1800      !
  181. 1810      ! dBm was selected. Round and check for limits.
  182. 1820      !
  183. 1830      Ampl=PROUND(Ampl,-2)
  184. 1840      IF Ampl>13 THEN Ampl=13
  185. 1850      IF Ampl<-60 THEN Ampl=-60
  186. 1860    END IF
  187. 1870    CONTROL @Ampl_disp;SET ("LABEL":VAL$(Ampl)&Btn$(Ampl_unit))
  188. 1880    SUBEXIT
  189. 1890 Cant_convert:   !
  190. 1900    DIALOG "ERROR",Ampl$&CHR$(10)&"is not recognizable as a number.";SET ("TITLE":"Can't convert to a number")
  191. 1910    GOTO 1620
  192. 1920  SUBEND
  193. 1930  SUB Set_offset
  194. 1940    COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  195. 1950    DIM Btn$(2)[6],Offs$[20]
  196. 1960    Btn$(0)=" V"
  197. 1970    Btn$(1)=" mV"
  198. 1980    Btn$(2)="Cancel"
  199. 1990    DIALOG "STRING","",Btn;SET ("VALUE":VAL$(Offset),"TITLE":"Enter DC Offset","DIALOG BUTTONS":Btn$(*),"DEFAULT BUTTON":0),RETURN ("VALUE":Offs$)
  200. 2000    IF Btn=2 THEN SUBEXIT  ! Cancel was selected
  201. 2010    ON ERROR GOTO Cant_convert
  202. 2020    Offset=VAL(Offs$)
  203. 2030    OFF ERROR
  204. 2040    IF Btn=1 THEN Offset=Offset*.001            ! mV button
  205. 2050    Offset=PROUND(Offset,-3)                    ! Round to 3 digits
  206. 2060    !
  207. 2070    IF ABS(Offset)>5 THEN Offset=SGN(Offset)*5  ! no more than 5 V offset
  208. 2080    CONTROL @Offs_disp;SET ("LABEL":VAL$(Offset)&" V offset")
  209. 2090    SUBEXIT
  210. 2100 Cant_convert:   !
  211. 2110    DIALOG "ERROR",Offs$&CHR$(10)&"is not recognizable as a number.";SET ("TITLE":"Can't convert to a number")
  212. 2120    GOTO 1990
  213. 2130  SUBEND
  214. 2140  SUB Toggle_am
  215. 2150    COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  216. 2160  !
  217. 2170  ! The menu widgets handle displaying whether modulation is on or
  218. 2180  ! off automatically. This routine determines what the state is and
  219. 2190  ! does the appropriate I/O.
  220. 2200  !
  221. 2210    STATUS @Am;RETURN ("VALUE":State)
  222. 2220    IF State THEN
  223. 2230  !
  224. 2240  ! Send the command to turn AM on
  225. 2250  !
  226. 2260    ELSE
  227. 2270  !
  228. 2280  ! Send the command to turn AM off
  229. 2290  !
  230. 2300    END IF
  231. 2310  SUBEND
  232. 2320  SUB Toggle_pm
  233. 2330    COM /Fgen/Freq,Ampl,Ampl_unit,Func,Offset,@Freq_disp,@Ampl_disp,@Offs_disp,@Func_disp,@Amplitude,@Am,@Pm
  234. 2340  !
  235. 2350  ! The menu widgets handle displaying whether modulation is on or
  236. 2360  ! off automatically. This routine determines what the state is and
  237. 2370  ! then does the appropriate I/O.
  238. 2380  !
  239. 2390    STATUS @Pm;RETURN ("VALUE":State)
  240. 2400    IF State THEN
  241. 2410  !
  242. 2420  ! Send the command to turn PM on
  243. 2430  !
  244. 2440    ELSE
  245. 2450  !
  246. 2460  ! Send the command to turn PM off
  247. 2470  !
  248. 2480    END IF
  249. 2490  SUBEND